<< Click to Display Table of Contents >>
Enable or Disable Log Sections |
Users can define which log Sections are enabled. Some Sections can be subdivided into Modules, so users can enable each Module separately. Each Module contains a configuration item with a question Enable log section/module?.
If items are not modified, the system automatically assumes that logs are not created. If items are modified, a No answer disables log creation, except for IOData Section, exemplified in details on Notes, and an Yes answer enables Section log. Modifying a Section value implies in changing all Module values inside that Section.
•IOData Section is an exception to this case. Its corresponding item is Disable IOData section. Not changing this item is the same as enabling this Section. Changing it by answering No to question Enable log section/module? disables this Section. •Changing these variables can be performed while Elipse Water is executing, and it is applied up to 30 seconds after execution. |
Available log Sections are described on the next table.
Log Sections and their respective Modules
Section |
Description |
---|---|
DB |
Shows errors on database or data discard operations, as well as results of operations executed on acquisition and execution threads |
ImportExport |
Log generated by Elipse Water Studio on data importing or exporting processes |
IOData |
Shows data read and written by E3Run |
Playback |
Log generated by E3Playback |
RECRaw |
Detailed log of REC communications. Available Modules on this Section are Client: Records request packages and Server: Records response packages |
Storage |
Allows tracking Storage operations. Available Modules on this Section are Dropped: Lists all values discarded by a Storage, Input: Lists all variations of Tag values linked to a Storage, and Stored: Displays all values sent by a Storage to a Database |
Sync |
Allows monitoring information synced between E3 Server and E3Run, and among E3 Servers in Hot-Standby mode. Available Modules on this Section are Alarm: Shows Alarm messages generated by E3Run, which are passed to an Alarm Summary kept by E3 Server and Vars: Shows changes made on E3 Server's persistent Tags database |
Undo |
Records system activities of Elipse Water Studio's Undo menu |
XdbSync |
Log with informative messages about the process of importing and syncing external electrical models |
There are special log Sections that record operations executed on a specific thread, as well as their duration. Only operations that last more than a certain time, whose default value is 100 ms, are logged. These logs allow checking when Elipse Water processing becomes slow, almost stopped. Available special log Sections are described next.
•Full: Main log gathering general information about E3 Server, E3Run, Elipse Water Studio, and Elipse Water Viewer execution. Available Modules are described on the next table.
Available Modules for Full Logs
Module |
Description |
---|---|
AccessChecker |
Thread responsible for checking Domain's permissions or access in E3 Server (E3Run) |
AlarmCallbackManager |
Thread responsible for receiving Alarm events from Remote Domains (E3Run) |
AlarmQueue |
Threads responsible for sending Alarm events |
AlarmServer |
E3Run's thread responsible for asynchronously sending Alarm events |
DBCallbackManager |
Thread responsible for receiving and storing in cache the statistics sent by the E3DBEngine process |
DefragDlg |
Thread responsible for the defragmentation of project and library files (E3Studio) |
DomainManager |
E3 Server Domain's state manager thread, that is, opens or closes the active Domain, updating a Domain based on changes on .dom files |
E3Admin |
E3 Admin's main thread |
E3Runtime |
E3Run's main thread, allows identifying locks or slowdowns during Elipse Water's execution |
E3Server |
E3 Server's main thread |
EventQueue |
E3 Server's threads responsible for sending asynchronous Link events |
Inactivity |
Threads responsible for checking Elipse Water Viewer's inactivity detection |
IOManager |
E3Run's thread responsible for receiving data generated by E3IoServers |
LicenseManager |
E3 Server's license check thread |
LinePrinter |
Thread responsible for sending asynchronous data to Line Printers (E3Run) |
Link2Stub |
E3Run's thread responsible for asynchronously sending Link events |
OpcCallback |
E3Run's or Elipse Water Studio's thread responsible for asynchronously receiving events from OPC Clients |
OPCGroup |
Thread responsible for sending notifications from Elipse Water's OPC Server (E3Run) |
PowerCADWarmUp |
Thread used to perform a PowerCAD pre-loading when opening Elipse Power Studio |
RECAppartment |
Thread used to manage the transmission of REC packets during a connection |
RECChannel |
Thread used to manage the transmission of data via network in REC connections |
RemoteDomain |
E3 Server's threads responsible for managing client connections from Remote Domains |
RemoteDomainsManager |
Thread where management of RemoteDomain sets occurs |
SafeServerSession |
Thread responsible for access or maintenance of retentive data from a Domain (E3Run) |
ServerControl |
E3 Server's threads responsible for managing a local or remote Domain server |
ServerControlCallback |
Thread responsible for sending notifications to E3 Admin (E3 Server) |
ServerControlMonitor |
E3 Server's thread responsible for automatically starting E3 Admin for logged in users |
ServerLinkManager |
E3 Server's thread implementing Link management |
ServerSubscriptionManager |
Thread responsible for managing Alarm signature connections |
StandbyAlgorithm |
E3 Server's thread implementing Hot-Standby algorithm decisions |
Studio |
Elipse Water Studio's main, or interface, thread |
StudyHubReceive |
Thread responsible for receiving notifications from Electrical Studies (E3Run) |
StudyHubSend |
Thread responsible for sending updates to Electrical Studies (E3Run) |
ThreadPool |
Reusable E3DBEngine process' thread responsible for executing Queries |
UaCallback |
Thread responsible for receiving notifications from OPC UA Clients (UaDriver) |
VideoRecorder |
Thread used to manage video recording in an E3Playback |
Viewer |
Elipse Water Viewer's main, or interface, thread, allows diagnosing Screen opening time and script execution time, among others |
XdbSync |
Thread responsible for the process of importing and syncing external electrical models |
•FullDB: Records operations of Elipse Water database access' threads, generated by E3Run and E3 Server. Available Modules are described on the next table.
Available Modules for FullDB Logs
Module |
Description |
---|---|
DBAcquisition |
Thread that sends application-generated data to queue files, the .e3i files |
DBCallback |
Thread that sends statistics about connections and operations finished or failed for the parent process |
DBEngineHost |
E3DBEngine process' main thread |
DBExec |
Thread that removes operations from queue files, the .e3o files, and executes commands on a database |
OCIThread |
OCI's (Oracle Call Interface) thread |
WatchDog |
E3DBEngine process' thread responsible for terminating this process if a lengthy operation is locked |
•FullEngine: Records detailed information on electrical model files in EDB format. This log records, for example, information about performance diagnosis, in addition to detailed results of several operations. Available Modules are described on the next table.
Available Modules for FullEngine Logs
Module |
Description |
---|---|
DistLoadModel |
Module responsible for calculations on Distribution Load Modeling Electrical Study |
ExternalReader |
Module responsible for calculations on External Reader Electrical Study |
LoadShedding |
Module responsible for calculations on Load Shedding Electrical Study |
PowerFlow |
Module responsible for calculations on Power Flow Electrical Study |
PslEngine |
Elipse Power's main module, responsible for handling Elipse Power requests |
SelfHealing |
Module responsible for calculations on Self-Healing Electrical Study |
StateEstimator |
Module responsible for calculations on State Estimator Electrical Study |
TopologyProcessor |
Module responsible for calculations on Topology Processor Electrical Study |
Workspace |
Module responsible for centralizing values of Measurements used by Electrical Studies |
•FullIO: Records activities on E3IoServer's threads. Available Modules are described on the next table.
Available Modules for FullIO Logs
Module |
Description |
---|---|
CallBack |
Thread for sending data collected by a Driver to E3Run |
Driver |
Thread executing a Driver |
IOServer |
E3IoServer's main thread, which receives Driver configuration and requests sent by E3Run |
WatchDog |
E3IoServer's thread responsible for terminating this process if any lengthy operation is locked |
•FullOPC: Records activities on OPC Client's threads. Available Modules are described on the next table.
Available Modules for FullOPC Logs
Module |
Description |
---|---|
OpcAsyncCreateServer |
OPC Client's threads responsible for isolating the connection and access to an OPC server |
OpcClient |
Thread where the OPC Client is executed |
OpcClientHost |
OPC Client's main thread |
OpcQueue |
Thread responsible for sending OPC Client's notifications asynchronously |
•FullUa: Records activities on OPC UA Client's threads. Available Modules are described on the next table.
Available Modules for FullUa Logs
Module |
Description |
---|---|
UaClient |
Thread where the OPC UA Client is executed |
UaClientHost |
OPC UA Client process' main thread |
UaQueue |
Thread responsible for sending notifications from OPC UA Clients (UaDriver) |
•PslEngine: Records general information on electrical model files in EDB format. Available Modules are described on the next table.
Available Modules for PslEngine Logs
Module |
Description |
---|---|
DistLoadModel |
Thread with information about Distribution Load Modeling Electrical Study |
ExternalReader |
Thread with information about External Reader Electrical Study |
LoadShedding |
Thread with information about Load Shedding Electrical Study |
PowerFlow |
Thread with information about Power Flow Electrical Study |
PslEngine |
Thread with global information about Elipse Power's main Module |
SelfHealing |
Thread with information about Self-Healing Electrical Study |
StateEstimator |
Thread with information about State Estimator Electrical Study |
TopologyProcessor |
Thread with information about Topology Processor Electrical Study |
Workspace |
Thread with information about Measurement values used by Electrical Studies |
NOTE |
Module configuration only has precedence over Section configuration. |