Reading Status

<< Click to Display Table of Contents >>

Reading Status

Read-Only

Use a PLC Tag to read an individual Status or use a Block Tag with 57 Elements to read all Statuses of a device. For Elipse E3, Elipse Power, or Elipse Water applications, this PLC or Block Tag is available via Tag Browser.

The next table contains a description of the parameters used in this PLC or Block Tag.

Parameters for reading Status

N1/B1

Address or Slave ID of a device

N2/B2

0 (zero)

N3/B3

0 (zero)

N4/B4

Status code, only for PLC Tags. For more information, please check table Status codes

 

To read an individual Status, via PLC or Block Tag, use the codes from the next table.

Status codes

N4/B4

Block Tag

Description

Automatic Multiplier

0

Element 1

Position of motor 1 (one), in degrees

100

1

Element 2

Position of motor 2 (two), in degrees

100

2

Element 3

Position of motor 3 (three), in degrees

100

3

Element 4

Position of motor 4 (four), in degrees

100

4

Element 5

Position of motor 5 (five), in degrees

100

5

Element 6

Position of motor 6 (six), in degrees

100

6

Element 7

Position of motor 7 (seven), in degrees

100

7

Element 8

Position of motor 8 (eight), in degrees

100

8

Element 9

Position of motor 9 (nine), in degrees

100

9

Element 10

Position of motor 10, in degrees

100

10

Element 11

Wind speed, in meters per second

None

11

Element 12

0, 0, 0, IN1, MNP1, MF1, DF1, MOV1. For more information on individual bits, please check table Bit Status

None

12

Element 13

0, 0, 0, IN2, MNP2, MF2, DF2, MOV2. For more information on individual bits, please check table Bit Status

None

13

Element 14

0, 0, 0, IN3, MNP3, MF3, DF3, MOV3. For more information on individual bits, please check table Bit Status

None

14

Element 15

0, 0, 0, IN4, MNP4, MF4, DF4, MOV4. For more information on individual bits, please check table Bit Status

None

15

Element 16

0, 0, 0, IN5, MNP5, MF5, DF5, MOV5. For more information on individual bits, please check table Bit Status

None

16

Element 17

0, 0, 0, IN6, MNP6, MF6, DF6, MOV6. For more information on individual bits, please check table Bit Status

None

17

Element 18

0, 0, 0, IN7, MNP7, MF7, DF7, MOV7. For more information on individual bits, please check table Bit Status

None

18

Element 19

0, 0, 0, IN8, MNP8, MF8, DF8, MOV8. For more information on individual bits, please check table Bit Status

None

19

Element 20

0, 0, 0, IN9, MNP9, MF9, DF9, MOV9. For more information on individual bits, please check table Bit Status

None

20

Element 21

0, 0, 0, IN10, MNP10, MF10, DF10, MOV10. For more information on individual bits, please check table Bit Status

None

21

Element 22

Night, 0, 0, 0, 0, 0, Wind Alarm, GPS Fail. For more information, please check table Bit information

None

22

Element 23

IN position for motor 1 (one), in degrees

10

23

Element 24

IN position for motor 2 (two), in degrees

10

24

Element 25

IN position for motor 3 (three), in degrees

10

25

Element 26

IN position for motor 4 (four), in degrees

10

26

Element 27

IN position for motor 5 (five), in degrees

10

27

Element 28

IN position for motor 6 (six), in degrees

10

28

Element 29

IN position for motor 7 (seven), in degrees

10

29

Element 30

IN position for motor 8 (eight), in degrees

10

30

Element 31

IN position for motor 9 (nine), in degrees

10

31

Element 32

IN position for motor 10, in degrees

10

32

Element 33

Parameter B for motor 1 (one), in millimeters

10

33

Element 34

Parameter B for motor 2 (two), in millimeters

10

34

Element 35

Parameter B for motor 3 (three), in millimeters

10

35

Element 36

Parameter B for motor 4 (four), in millimeters

10

36

Element 37

Parameter B for motor 5 (five), in millimeters

10

37

Element 38

Parameter B for motor 6 (six), in millimeters

10

38

Element 39

Parameter B for motor 7 (seven), in millimeters

10

39

Element 40

Parameter B for motor 8 (eight), in millimeters

10

40

Element 41

Parameter B for motor 9 (nine), in millimeters

10

41

Element 42

Parameter B for motor 10, in millimeters

10

42

Element 43

Azimuth of axis, in degrees

10

43

Element 44

Tilt of axis, in degrees

10

44

Element 45

Pitch A, in centimeters (distance between two axes)

None

45

Element 46

Pitch B, in centimeters (distance between two axes by the motor side)

None

46

Element 47

Width of PV module along east-west direction, in millimeters

None

47

Element 48

Threshold of wind alarm, in meters per second

None

48

Element 49

Parameter A, in millimeters (parameter of lower motor arm)

None

49

Element 50

Parameter B, in millimeters (parameter of upper motor arm)

10

50

Element 51

Parameter C, in millimeters (parameter of vertical motor arm)

None

51

Element 52

Wind-safe position, in degrees

10

52

Element 53

Extended address (SKC serial number)

None

53

Element 54

Night position, in degrees

10

54

Element 55

Gamma limit, in degrees

10

55

Element 56

Wind's end time, in minutes

None

56

Element 57

Pre-maximum wind, in meters per second

None

 

NOTE

Readings with an automatic multiplier represent the decimal points of the read value, that is, via protocol, data comes to this Driver only as an Integer data type, and users must divide this value by its respective multiplier, so that Tags can display these values with decimal points.

 

For the sequence from the N4 parameter equal to 11 (Element 12) to the N4 parameter equal to 20 (Element 21), use the next table to identify the Status of each bit.

Bit Status

Bit

Description

7

Not used

6

Not used

5

Not used

4

IN sensor enabled

3

Motor not used

2

Motor on failure

1

Spinning direction of sensor

0

Moving sensor

 

For the N4 parameter equal to 21 (Element 22), use the next table to identify information for each bit.

Bit information

Bit

Description

7

Night

6

Not used

5

Not used

4

Not used

3

Not used

2

Not used

1

Wind alarm

0

GPS on failure

Was this page useful?