How to Configure a Device from A Series Using an AJ71UC24 Adapter

<< Click to Display Table of Contents >>

 

How to Configure a Device from A Series Using an AJ71UC24 Adapter

Before establishing communication, users must configure dip-switches and the Mode Setting switch according to the adapter to use, RS-232 or RS-485. For RS-232 connectors, the Mode Setting switch must be set to 1 (one, Protocol 1). For RS-485 connectors, the Mode Setting switch must be set to 5 (five, Protocol 1 for RS-485). Dip-switches must be configured according to the next tables.

Available options for Dip-Switches

Dip-Switch

Position

Notes

SW-11

OFF

 

SW-12

ON

8 (eight) bits per character

SW-13

 

Please check the next table

SW-14

 

Please check the next table

SW-15

 

Please check the next table

SW-16

ON

Parity enabled

SW-17

ON

Even parity

SW-18

OFF

One stop bit

SW-21

ON

Checksum enabled

SW-22

ON

Writing during execution enabled

SW-23

ON

Computer link

SW-24

OFF

Not used

 

Baud rate configuration for SW-13, SW-14, and SW-15 Switches

Baud Rate

SW-13

SW-14

SW-15

2400

ON

ON

OFF

4800

OFF

OFF

ON

9600

ON

OFF

ON

19200

OFF

ON

ON