Inquiry or Parameter Transfer

<< Click to Display Table of Contents >>

 

Inquiry or Parameter Transfer

Reading or Writing

 

N1 or B1

2 (two)

N2 or B2

Inquiry or Parameter. For more information, please check the next table

N3 or B3

0 (zero)

N4 or B4

0 (zero)

 

For detailed information about each type of Block Tag or PLC Tag, please check topic Parameter Details.

 

NOTE

The EL and EV options return a list.

 

Possible values for the N2 parameter

N2

Option

Description

Block Size

Operation

0

EX

Report external states

9 (nine)

Read-only

1

SH

Report service history

3 (three)

Read-only

2

IC

Report input configuration

6 (six)

Read-only

3

HS

Report hydraulic states

6 (six)

Read-only

4

OC

Report output configuration

8 (eight)

Read-only

5

MC

Report main configuration

13

Read-only

6

CC

Report current counter

3 (three)

Reading and writing

7

SC

Report service configuration

2 (two)

Read-only

8

VS

Report version

10

Read-only

9

JL

Query name of loaded job

1 (one, PLC Tag)

Reading and writing

10

EL

Query error list

2 (two, list)

Read-only

11

EV

Query event list

8 (eight, list)

Read-only

12

JB

Inquiry for the current print job

1 (one, PLC Tag)

Read-only

13

SM

Get mail status

5 (five)

Read-only

14

DL

Query date and time

7 (seven)

Reading and writing

15

RS

Query status of data

5 (five)

Read-only

16

GW

Query WYSIWYG

1 (one, PLC Tag)

Read-only

17

MR

Mail record

1 (one, PLC Tag)

Write-only

18

CM

Config mail

1 (one, PLC Tag)

Write-only

19

ET

External text

1 (one, PLC Tag)

Write-only

20

FL

Fix block length

1 (one, PLC Tag)

Write-only

21

RC

Reset counter

2 (two)

Write-only

22

PR

Print parameter

2 (two)

Write-only

Was this page useful?