Parameter Details

<< Click to Display Table of Contents >>

 

Parameter Details

For detailed information about parameters and their Elements, please check document Leibinger Jet3 Interface Protocol, include in the installation of this Driver.

EX (External States, Block Tag with nine Elements)

Element

Description

1

Actual Speed (Integer)

2

Inputs (Integer)

3

Maximum Speed (Integer)

4

Direction (Integer)

5

Print Go (Integer)

6

Reserved

7

Reserved

8

Reserved

9

Reserved

 

SH (Service History, Block Tag with three Elements)

Element

Description

1

Operating Hours (Integer)

2

Last Service Hours (Integer)

3

Last Service Date (Date and Time)

 

IC (Input Configuration, Block Tag with six Elements)

Element

Description

1

Input 1 (Integer)

2

Input 2 (Integer)

3

Input 3 (Integer)

4

Input 4 (Integer)

5

Input 5 (Integer)

6

Input 6 (Integer)

 

HS (Hydraulic State, Block Tag with six Elements)

Element

Description

1

Act Falltime (Integer)

2

Act Press (Integer)

3

Act Suctpump (Integer)

4

Diaphragm Position (Integer)

5

Mix-Value (Integer)

6

State (Integer)

 

OC (Output Configuration, Block Tag with eight Elements)

Element

Description

1

Output 1 (Integer)

2

Output 2 (Integer)

3

Output 3 (Integer)

4

Output 4 (Integer)

5

Output 5 (Integer)

6

Output 6 (Integer)

7

Output 7 (Integer)

8

Output 8 (Integer)

 

MC (Main Configuration, Block Tag with 13 Elements)

Element

Description

1

Direct Print (Integer)

2

Encoder Setting (Integer)

3

Reserved

4

Reserved

5

Reserved

6

Set Fall Time (Integer)

7

Set Pressure (Integer)

8

Reserved

9

Set Visto Correction (Integer)

10

System Frequency (Integer)

11

Ink number (Integer)

12

Interval Time On (String in the format HH:MM)

13

Interval Time Off (String in the format HH:MM)

 

CC (Current Counter, Block Tag with three Elements)

Element

Description

1

Product Counter (Integer)

2

Stop after n Products (Integer)

3

Total print counter (Integer)

 

SC (Service Configuration, Block Tag with two Elements)

Element

Description

1

Service Hour Interval (Integer)

2

Service Year Interval (Integer)

 

VS (Version, Block Tag with 10 Elements)

Element

Description

1

FPGA Version (String)

2

RIP Software Version (String)

3

SDS Software Version (String)

4

FEP Software Version (String)

5

Kernel Version (String)

6

System Type (String)

7

Language Pack (String)

8

Font Pack (String)

9

LJ Version (String)

10

Type (String)

 

JL (Job Load, PLC Tag)

Element

Description

1

Job name (String with information about a path)

 

EL (Error List, Block Tag with two Elements and return as a list)

Element

Description

1

Error Time (Date and Time)

2

Error Code (Integer)

 

EV (Event List, Block Tag with nine Elements and return as a list)

Element

Description

1

Event Time (Date and Time)

2

Compressor Pulse (Integer)

3

Sips of solvent (Integer)

4

Sips of ink (Integer)

5

Mix Ratio (Integer)

6

Pressure (Integer)

7

Diaphragm Position (Integer)

8

Fill Time (Integer)

9

Machine State (Integer)

 

JB (Job, PLC Tag)

Element

Description

1

LJScript (String)

 

SM (Mail Status, Block Tag with five Elements)

Element

Description

1

Fifo Depth (Integer)

2

Fifo Entries (Integer)

3

LastStartedPrintNo (Integer)

4

StopAtNo (Integer)

5

LastStartedPrintNoWasFinished (Integer)

 

DL (Date Time, Block Tag with seven Elements)

Element

Description

1

Year (Integer)

2

Month (Integer)

3

Day (Integer)

4

Weekday (Integer between 0: Sunday and 6: Saturday)

5

Hour (Integer)

6

Minute (Integer)

7

Second (Integer)

 

RS (Machine State, Block Tag with five Elements)

Element

Description

1

Nozzle State (Integer)

2

State of Machine (Integer)

3

Error (Integer)

4

Head cover (Integer)

5

Act Speed (Integer)

 

GW (WYSIWYG Data, PLC Tag)

Element

Description

1

WYSIWYG data (String)

 

MR (Mail Record, PLC Tag)

Element

Description

1

String

 

CM (Config Mail, PLC Tag)

Element

Description

1

StopAtNo (Integer)

 

ET (External Text, Tag)

Element

Description

1

String

 

FL (Fix Block Length, PLC Tag)

Element

Description

1

Block length in bytes (Integer)

 

RC (Reset Counter, Block Tag with two Elements)

Element

Description

1

Counter Number (Integer)

2

Start Value (Integer)

 

PR (Print Parameter, Block Tag with two Elements)

Element

Description

1

Print parameter type that must be changed (Integer)

2

New value for the parameter (Integer)

Was this page useful?