<< Click to Display Table of Contents >>
FieldId |
Unique identifier of the column of this Field on an E3Alarm. Possible values for this property are described on the next table.
Possible values for the FieldId property
Value |
Column |
Description |
---|---|---|
1 |
AckRequired |
Event needs manual (True) or automatic (False) acknowledgment |
2 |
Acked |
Event was acknowledged or not |
3 |
ActorID |
Name of the operator that acknowledged this Event |
4 |
ChangeMask |
Not used and its value is always equal to 0 (zero) |
5 |
ConditionName |
Condition name, in case of an Alarm (Dead Band, Digital, Discrete, Level, or Rate of Change) |
6 |
ConditionActive |
Indicates whether the Alarm Source is in Alarm or not |
7 |
Cookie |
Value used internally by the Alarm Server |
8 |
Enabled |
Determines whether Alarm verification is enabled or not |
9 |
EventCategory |
Event category. For Alarms, possible values are Dead Band, Digital, Discrete, Level, or RateOfChange |
10 |
EventType |
Type of Event |
11 |
Message |
Text configured in the Alarm Source |
12 |
Quality |
Quality of the Alarm Source value at the moment of an Event |
13 |
Severity |
Value of severity configured in the Alarm Source |
14 |
Source |
Expression used to evaluate Alarm conditions |
15 |
SubConditionName |
Name of a sub-condition, if this is an Alarm Event |
16 |
EventTime |
Date and time of an Event |
17 |
EventTimeUTC |
Date and time of an Event, in UTC format |
18 |
CurrentValue |
Current value of an Alarm Source, as a floating-point number |
19 |
AlarmArea |
Name of an Area to which an Alarm Source belongs |
20 |
AlarmSourceName |
Name of an Alarm Source |
21 |
EventTimeMS |
Date and time of an Event, in milliseconds |
22 |
InTime |
Date and time of entering an Event |
23 |
InTimeMS |
Date and time of entering an Event, in milliseconds |
24 |
OutTime |
Date and time of leaving an Event |
25 |
OutTimeMS |
Date and time of leaving an Event, in milliseconds |
26 |
AckTime |
Date and time of acknowledging an Event |
27 |
AckTimeMS |
Date and time of acknowledging an Event, in milliseconds |
28 |
FullAlarmSourceName |
Full name of an Alarm Source |
29 |
FormattedValue |
Formatted value |
30 |
InTimeDbl |
Date and time of entering an Event, as a floating-point number |
31 |
OutTimeDbl |
Date and time of leaving an Event, as a floating-point number |
32 |
AckTimeDbl |
Date and time of acknowledging an Event, as a floating-point number |
33 |
EventTimeDbl |
Date and time of an Event, as a floating-point number |
34 |
EventCLSID |
Unique identification of an Event |
35 |
ActiveSource |
Active Measurement Source of an Alarm Source at the moment of an Event |
36 |
Unbound |
Indicates whether an Event is linked to an Alarm Source or not |
37 |
Deleted |
Indicates whether an Event was removed or not |
38 |
AllowShelving |
Indicates whether an Alarm or Event allows shelving or not |
39 |
Shelved |
Indicates whether an Alarm or Event was shelved or not |
40 |
ShelvedTime |
Date and time of shelving an Alarm or Event |
41 |
ShelvedOutTime |
Date and time of unshelving or 0 (zero) if an Alarm or Event is not yet unshelved |
42 |
ShelveDuration |
Duration time, in minutes, that an Alarm or Event has been shelved |
43 |
ShelveMaxDuration |
Maximum duration, in minutes, that an Alarm or Event can remain shelved |
44 |
ShelveCount |
Number of times an Alarm or Event was shelved |
45 |
ShelveMaxCount |
Maximum number of shelvings allowed for an Alarm or Event |
46 |
ShelveActorID |
Name of the operator responsible for shelving an Alarm or Event |
47 |
ShelveReason |
Reason for shelving an Alarm or Event |
48 |
E3TimeStamp |
Date and time of an Event occurrence in Elipse Water format |
49 |
Suppressed |
Indicates whether an Alarm was suppressed |
50 |
SuppressedTime |
Date and time of suppressing an Alarm |
51 |
SequentialNumber |
Sequential number of an Alarm |
52 |
AlarmState |
Current status of an Alarm |
53 |
ShelvedExpirationTime |
Indicates the programmed date and time for this Alarm or Event to leave its shelving condition |
54 |
OutOfService |
Identifies whether an Alarm was suppressed using the Out-of-Service type |
55 |
OutOfServiceTime |
Date and time an Alarm was suppressed using the Out-of-Service type |
56 |
ReturnToServiceTime |
Date and time in which an Alarm suppressed using the Out-of-Service type returned to normal operation |
57 |
OutOfServiceReason |
Reason by which an Alarm was suppressed using the Out-of-Service type by an operator |
58 |
OutOfServiceActorID |
Operator that performed the suppression of an Alarm using the Out-of-Service type |