<< Click to Display Table of Contents >>
FieldId |
Unique identifier of the column of this Field on an E3Alarm. Possible values for this property are described on the next table.
Possible values for the FieldId property
Value |
Column |
Description |
|---|---|---|
1 |
AckRequired |
Event needs manual (True) or automatic (False) acknowledgment |
2 |
Acked |
Event was acknowledged or not |
3 |
ActorID |
Name of the operator that acknowledged this Event |
4 |
ChangeMask |
Not used and its value is always equal to 0 (zero) |
5 |
ConditionName |
Condition name, in case of an Alarm (Dead Band, Digital, Discrete, Level, or Rate of Change) |
6 |
ConditionActive |
Indicates whether the Alarm Source is in Alarm or not |
7 |
Cookie |
Value used internally by the Alarm Server |
8 |
Enabled |
Determines whether Alarm verification is enabled or not |
9 |
EventCategory |
Event category. For Alarms, possible values are Dead Band, Digital, Discrete, Level, or RateOfChange |
10 |
EventType |
Type of Event |
11 |
Message |
Text configured in the Alarm Source |
12 |
Quality |
Quality of the Alarm Source value at the moment of an Event |
13 |
Severity |
Value of severity configured in the Alarm Source |
14 |
Source |
Expression used to evaluate Alarm conditions |
15 |
SubConditionName |
Name of a sub-condition, if this is an Alarm Event |
16 |
EventTime |
Date and time of an Event in local computer's time |
17 |
EventTimeUTC |
Date and time of an Event, adjusted to UTC (Coordinated Universal Time) format. For applications created in versions previous to version 7.0, this value corresponds to the value of the EventTime column without timezone adjustment. For more information, please check topic Properties Tab on Elipse Power User's Manual |
18 |
CurrentValue |
Current value of an Alarm Source, as a floating-point number |
19 |
AlarmArea |
Name of an Area to which an Alarm Source belongs |
20 |
AlarmSourceName |
Name of an Alarm Source |
21 |
EventTimeMS |
Date and time of an Event, in milliseconds |
22 |
InTime |
Date and time of entering an Event |
23 |
InTimeMS |
Date and time of entering an Event, in milliseconds |
24 |
OutTime |
Date and time of leaving an Event |
25 |
OutTimeMS |
Date and time of leaving an Event, in milliseconds |
26 |
AckTime |
Date and time of acknowledging an Event |
27 |
AckTimeMS |
Date and time of acknowledging an Event, in milliseconds |
28 |
FullAlarmSourceName |
Full name of an Alarm Source |
29 |
FormattedValue |
Formatted value |
30 |
InTimeDbl |
Date and time of entering an Event, as a floating-point number |
31 |
OutTimeDbl |
Date and time of leaving an Event, as a floating-point number |
32 |
AckTimeDbl |
Date and time of acknowledging an Event, as a floating-point number |
33 |
EventTimeDbl |
Date and time of an Event, as a floating-point number |
34 |
EventCLSID |
Unique identification of an Event |
35 |
ActiveSource |
Active Measurement Source of an Alarm Source at the moment of an Event |
36 |
Unbound |
Indicates whether an Event is linked to an Alarm Source or not |
37 |
Deleted |
Indicates whether an Event was removed or not |
38 |
AllowShelving |
Indicates whether an Alarm or Event allows shelving or not |
39 |
Shelved |
Indicates whether an Alarm or Event was shelved or not |
40 |
ShelvedTime |
Date and time of shelving an Alarm or Event |
41 |
ShelvedOutTime |
Date and time of unshelving or 0 (zero) if an Alarm or Event is not yet unshelved |
42 |
ShelveDuration |
Duration time, in minutes, that an Alarm or Event has been shelved |
43 |
ShelveMaxDuration |
Maximum duration, in minutes, that an Alarm or Event can remain shelved |
44 |
ShelveCount |
Number of times an Alarm or Event was shelved |
45 |
ShelveMaxCount |
Maximum number of shelvings allowed for an Alarm or Event |
46 |
ShelveActorID |
Name of the operator responsible for shelving an Alarm or Event |
47 |
ShelveReason |
Reason for shelving an Alarm or Event |
48 |
E3TimeStamp |
Date and time of an Event occurrence in Elipse Power format |
49 |
Suppressed |
Indicates whether an Alarm was suppressed |
50 |
SuppressedTime |
Date and time of suppressing an Alarm |
51 |
SequentialNumber |
Sequential number of an Alarm |
52 |
AlarmState |
Current status of an Alarm |
53 |
ShelvedExpirationTime |
Indicates the programmed date and time for this Alarm or Event to leave its shelving condition |
54 |
OutOfService |
Identifies whether an Alarm was suppressed using the Out-of-Service type |
55 |
OutOfServiceTime |
Date and time an Alarm was suppressed using the Out-of-Service type |
56 |
ReturnToServiceTime |
Date and time in which an Alarm suppressed using the Out-of-Service type returned to normal operation |
57 |
OutOfServiceReason |
Reason by which an Alarm was suppressed using the Out-of-Service type by an operator |
58 |
OutOfServiceActorID |
Operator that performed the suppression of an Alarm using the Out-of-Service type |