•Added a note on the description of KeyUp, KeyDown (Screens and Screen Objects), and KeyPress (Microsoft Forms, E3Alarm, and E3Browser) events on Elipse E3 Reference and Scripts Manual with a link for a full list of key codes available for these events. This bug occurred since v1.20.385.
•Updated the description of the Font property of Check Box, Option Button, Combo Box, Command Button, Label, List Box, Toggle Button, and Text Box objects of MS Forms on Elipse E3 Reference and Scripts Manual to remove the indication that this property cannot be used by script.
•Fixed the description of the Remove method of E3Chart's Collection of Pens on Elipse E3 Reference and Scripts Manual to indicate that this method accepts a Pen's index as well as a Pen's name to remove. This bug occurred since v3.2.267.
•Removed the example on the description of Splitter's SplitLink property on Elipse E3 Reference and Scripts Manual. This bug occurred since v2.5.177.
•Updated the description of Splitter's SplitValue property on Elipse E3 Reference and Scripts Manual to include its behavior also at run time. This bug occurred since v3.0.168.
•Updated the Properties tab figure on topic Programming in Elipse E3 - Getting References to Objects - Accessing Objects from the ElipseX Itself of Elipse E3 Reference and Scripts Manual to match it to topic's text. This bug occurred since v1.22.34.
•Updated the description of Viewer's EnableInactivity property on Elipse E3 Reference and Scripts Manual to indicate that this property cannot be changed by script. This bug occurred since v1.20.325.
•Updated the example of Viewer's GetFrame method on Elipse E3 Reference and Scripts Manual. This bug occurred since v1.0.0.
•Fixed the name of the field that allows filtering an alarm by area on the description of E3Alarm's CustomFilter property on Elipse E3 Reference and Scripts Manual. This bug occurred since v4.5.134.
•Added information about discrete alarm sources on the description of Event's ConditionName, EventCategory, and SubConditionName properties on Elipse E3 Reference and Scripts Manual. This bug occurred since v4.0.192.
•Added more information to the description of the Value used for scan option on topic E3Chart - Settings - Pens Tab, table Available options for Connection Type tab on Elipse E3 User's ManualElipse E3 User's Manual. This bug occurred since v3.5.172.
•Updated topic Frequently Asked Questions - Remote Domains on Elipse E3 User's Manual to describe the procedure to view and acknowledge alarms in Remote Domains. This bug occurred since v3.1.234.
•Updated the description of the Keep data from the last ... <Backup Table> option of Storage, Historic, and Alarm Server objects on Elipse E3 User's Manual. This bug occurred since v1.21.113.