Collect Data

<< Click to Display Table of Contents >>

 

Collect Data

Read-Only

 

Device

Serial number of a LogBox 3G device registered on NOVUS Cloud service

B1

4 (four)

B2

Channel number to read. For more information, please check table Available options for the N2/B2 parameter

B3

Not used, leave it in 0 (zero)

B4

Not used, leave it in 0 (zero)

 

This Block Tag is a list with N values, where N is the number of data values read and determined in the time span between the initial date and time and the final date and time written to the Request Collect Tag. If there is no data, it returns an empty list.

Element 1: List of values referring to the selected device and Channel

Element 2: List of values referring to the GPS latitude coordinate

Element 3: List of values referring to the GPS longitude coordinate

 

Each block returned on this list contains the registered timestamp of a record reported on NOVUS Cloud service.

 

NOTES

This table requires a writing to the Request Collect Tag, with an initial and final date and time interval, to command its data transfer in background.

If the number of records requested per date exceeds 65535, users must repeat this Tag's reading until Status Read Tag leaves the status 4 (four, loaded with data).