[P] Parameters

<< Click to Display Table of Contents >>

 

[P] Parameters

P1

Number of a serial port. Possible values are 1: COM1, 2: COM2, 3: COM3, or 4: COM4

P2

Number of a Moby channel (MobyChannel). This value refers to the number of the channel wherethe SLG, SIM, or SLA device is addressed

P3

Not used, leave it in 0 (zero)

P4

Time-out, in milliseconds

 

This Driver also has extra configurations, which determine values to start communication with an antenna device. These configurations are described on the next table.

Extra configurations of Siemens Moby Driver

Configuration

Description

Default value

Mode

Operation mode. Possible values are MOBY I or MOBY U

MOBY U

Multitag/bunch

Number of MDS devices that can be processed in the are of an antenna, or zone 1 (one). Possible values range between 1 (one) and 12

1 (one)

Standby time

Time in which an MDS device must enter a stand-by mode after an MDS command is executed. This means that an MDS device remains active to process the next command, which must appear during that stand-by time, without delay. This value specifies a factor of 7 (seven) milliseconds and not an absolute time. For example, the value 10 corresponds to 10 × 7 ms, or 70 ms. The value 0 (zero) indicates the absence of a stand-by, that is, an MDS device enters inactivity mode again after each communication with an MDS command. Values between 1 (one) and 200 correspond to values between 7 ms and 1400 ms

30

Proximity switch mode (fcon)

Values of modes. Possible values are 0: Mode 1 or without proximity switches or SLG syncing, 1: Mode 2 or one or two proximity switches are turned on in an OR logical operation. While the first or second switch is turned on, the field remains turned on. Otherwise, the field remains turned off, 2: Mode 3 or one or two proximity switches. The first switch turns on the field and the second switch turns off the field. When there are two proximity switches and the time of the proximity field is configured, the field is automatically turned off when the second proximity switch does not change its status inside that proximity time. When there are no proximity switch, the time of the proximity switch must be configured. After that time, the field is automatically turned off, or 3: Mode 4 or SLG syncing. For more information, please check Moby U Manual for configuration, installation and services

0 (zero)

Distance limit (dili)

Distance limit. Values directly correspond to distances in meters, divided by 10. For example, the value 5 (five) corresponds to 0,5 m, the value 10 corresponds to 1,0 m, the value 15 corresponds to 1,5 m, the value 20 corresponds to 2,0 m, the value 25 corresponds to 2,5 m, the value 30 corresponds to 3,0 m, and the value 35 corresponds to 3,5 m. Users must add the value 128 when the sending capacity is reduced

30

Proximity switch time (ftim)

Time value. Possible values are 0: ftim equal to 0 (zero, when fcon is equal to zero) or 1 to 255: ftim between 1 (one) and 255 seconds

0 (zero)

ANW

Select this option for operations with presence check and deselect this option for operations without presence check

Selected