Table of Commands

<< Click to Display Table of Contents >>

 

Table of Commands

The next table contains a list of commands supported by this Driver.

Commands supported by the FluxWatts Driver

N1/B1

N2/B2

N4/B4

Command

Type

Description

Additional Information

2

0 (zero, read-only)

Not used

RESPONSE_DETECTOR_EVENT

Block Tag

Returns event information. The Elements of this Block Tag are 1: Communication Detector ID (Number), 2: Communication Detector Name (Text), 3: Detector ID (Number), 4: Detector Name (Text), 5: Zone ID (Number), 6: Zone Name (Text), 7: Zone Reference (Number), 8: Response Type (Text), 9: Event Type (Text), 10: Event ID (Number), 11: Active (Boolean), and 12: Level (Number)

Possible events are NO_VIDEO, SERVICE_LEVEL_x, COMMUNICATION_ERROR, STOPPED_VEHICLE, SPEED_DROP, INVERSE_DIRECTION, SMOKE, BAD_VIDEO, DIGITAL_INPUT, USER_EVENT_x, CONFIG_CHANGED, ZONE_ACTIVE, OUTPUT_GROUP_ACTIVE, REBOOT_EVENT, NOREDUNDANTPWR, PTZ_OUT_OF_HOME, PEDESTRIAN, CAMERAMOVED, FALLENOBJECT, UNDERSPEED, OVERSPEED, REDUNDANT_ERROR, INHIBITION_CHANGED, NIGHTMODE_EVENT, IO_EXPANSION_ERROR, SCENARIO_CHANGED, PRESENCE, BAD_PRESENCE_QUALITY, TEMPERATURE, CHANNEL_2_ON, RECORDING_ERROR, PRESENCE_LEVEL_x, PTZ_PRESET_x, RECORDING_EVENT, or BICYCLE_PRESENCE

26

0 (zero, read-only)

Not used

RESPONSE_COMBOARD_EVENT

Block Tag

Returns event information. The Elements of this Block Tag are 1: Communication Detector ID (Number), 2: Communication Detector Name (Text), 3: Zone ID (Number), 4: Zone Name (Text), 5: Zone Reference (Number), 6: Response Type (Text), 7: Event Type (Text), 8: Event ID (Number), 9: Active (Boolean), and 10: Level (Number)

Possible events are COMMUNICATION_ERROR, CONFIG_CHANGED, REBOOT_EVENT, REDUNDANT_ERROR, or VIDEO_SLOT

35

0 (zero, read-only)

Not used

RESPONSE_TMS_SERVER_EVENT

Block Tag

Returns event information. The Elements of this Block Tag are 1: TMS Server ID (Number), 2: TMS Server Name (Text), 3: Response Type (Text), 4: Event Type (Text), 5: Event ID (Number), and 6: Active (Boolean)

Possible event is COMMUNICATION_ERROR

36

0 (zero, read-only)

Not used

RESPONSE_VIDEO_STORAGE_SERVER_EVENT

Block Tag

Returns event information. The Elements of this Block Tag are 1: Video Storage Server ID (Number), 2: Video Storage Server Name (Text), 3: Response Type (Text), 4: Event Type (Text), 5: Event ID (Number), and 6: Active (Boolean)

Possible event is COMMUNICATION_ERROR

39

0 (zero, read-only)

Not used

RESPONSE_DATABASE_SERVER_EVENT

Block Tag

Returns event information. The Elements of this Block Tag are 1: Database Server ID (Number), 2: Database Server Name (Text), 3: Response Type (Text), 4: Event Type (Text), 5: Event ID (Number), and 6: Active (Boolean)

Possible event is COMMUNICATION_ERROR

40

0 (zero, read-only)

Not used

RESPONSE_DETECTOR_GROUP_EVENT

Block Tag

Returns event information. The Elements of this Block Tag are 1: ID of the Parent Detector Group (Number), 2: Detector Group ID (Number), 3: Detector Group Name (Text), 4: Scenario ID (Number), 5: Scenario Name (Text), 6: Response Type (Text), 7: Event Type (Text), 8: Event ID (Number), and 9: Active (Boolean)

Possible events are INHIBITION_CHANGED or SCENARIO_CHANGED

43

0 (zero, read-only)

Not used

RESPONSE_STREAMING_SERVER_EVENT

Block Tag

Returns event information. The Elements of this Block Tag are 1: Streaming Server ID (Number), 2: Streaming Server Name (Text), 3: Response Type (Text), 4: Event Type (Text), 5: Event ID (Number), and 6: Active (Boolean)

Possible event is COMMUNICATION_ERROR

49

0 (zero, read-only)

Not used

RESPONSE_SYSTEM_EVENT

Block Tag

Returns event information. The Elements of this Block Tag are 1: Database Server ID (Number), 2: Database Server Name (Text), 3: Response Type (Text), 4: Event Type (Number), 5: Event ID (Number), and 6: Active (Boolean)

Possible event is the numeric value of the system's event ID

50

0 (zero, read-only)

Not used

RESPONSE_NVR_SERVER_EVENT

Block Tag

Returns event information. The Elements of this Block Tag are 1: NVR Server ID (Number), 2: NVR Server Name (Text), 3: Response Type (Text), 4: Event Type (Text), 5: Event ID (Number), and 6: Active (Boolean)

Possible event is COMMUNICATION_ERROR

51

0 (zero, read-only)

Not used

RESPONSE_PLUGIN_EVENT

Block Tag

Returns event information. The Elements of this Block Tag are 1: Plug-in Name (Text), 2: ID of the Parent Detector Group (Number), 3: Plug-in Device ID (Number), 4: Plug-in Device Name (Text), 5: Response Type (Text), 6: Event Type (Text), 7: Event ID (Number), 8: Active (Boolean), 9: Level (Number), 10: Scenario ID, in scenario change events (Number), and 11: Extra Info (Text)

The event type depends on the plug-in

01

0 (zero, read-only)

Not used

RESPONSE_ZONE_INTEGRATED_DATA

Block Tag

Returns data information. The Elements of this Block Tag are 1: Communication Detector ID (Number), 2: Communication Detector Name (Text), 3: Detector ID (Number), 4: Detector Name (Text), 5: Zone ID (Number), 6: Zone Name (Text), 7: Zone Reference (Number), 8: Occupancy (Number), 9: Confidence (Number), 10: Length (Number), 11: Headway (Number), 12: Density (Number), 13: Headway Square (Number), 14: Number of Classes (Number), and 15: Block Tag with the Elements 1: Number of Vehicles (Number), 2: Speed (Number), 3: Gap Time (Number), 4: Speed Square (Number), and 5: Gap Square (Number)

The size of the list of classes block is defined by the value of Element 15, number of classes

33

0 (zero, read-only)

Not used

RESPONSE_ZONE_INDIVIDUAL_DATA

Block Tag

Returns data information. The Elements of this Block Tag are 1: Communication Detector ID (Number), 2: Communication Detector Name (Text), 3: Detector ID (Number), 4: Detector Name (Text), 5: Zone ID (Number), 6: Zone Name (Text), 7: Zone Reference (Number), 8: Sequence Number (Number), 9: Milliseconds (Number), 10: Confidence (Number), 11: Length (Number), 12: Class (Number), 13: Speed (Number), and 14: Gap Time (Number)

 

42

0 (zero, read-only)

Not used

RESPONSE_ZONE_FLOW_DATA

Block Tag

Returns data information. The Elements of this Block Tag are 1: Communication Detector ID (Number), 2: Communication Detector Name (Text), 3: Detector ID (Number), 4: Detector Name (Text), 5: Zone ID (Number), 6: Zone Name (Text), 7: Zone Reference (Number), 8: Occupancy (Number), and 9: Flow Speed (Number)

 

47

0 (zero, read-only)

Not used

RESPONSE_ZONE_PRESENCE_DATA

Block Tag

Returns data information. The Elements of this Block Tag are 1: Communication Detector ID (Number), 2: Communication Detector Name (Text), 3: Detector ID (Number), 4: Detector Name (Text), 5: Zone ID (Number), 6: Zone Name (Text), 7: Zone Reference (Number), 8: Number of Vehicles (Number), and 9: Occupancy (Number)

 

52

0 (zero, read-only)

Not used

RESPONSE_ZONE_BICYCLE_DATA

Block Tag

Returns data information. The Elements of this Block Tag are 1: Communication Detector ID (Number), 2: Communication Detector Name (Text), 3: Detector ID (Number), 4: Detector Name (Text), 5: Zone ID (Number), 6: Zone Name (Text), 7: Zone Reference (Number), and 8: Bicycle Count (Number)

 

49

1 (one,write-only)

0: Not agreed ou 1: Agreed

RESPONSE_CONFIRM_EVENT

Number

The value of the Tag is the ID of the event to confirm

Only works when the Watts SDK plug-in is configured to set an ID for each event

 

NOTES

When an information is not available, such as a disabled event ID or unmapped zones, the value of the Element is equal to NULL.

Event IDs are only available when the Add Flux event Ids to all event related responses option is selected in the Watts SDK plug-in settings.

Messages are received asynchronously by this Driver, which has a maximum storage size. If messages are lost, it is recommended to decrease a Tag's scan time.

Was this page useful?