Configuration Parameters

<< Click to Display Table of Contents >>

 

Configuration Parameters

Read-Only

 

B1

4

B2

Varies from 0 (zero) to 23 or from 27 to 33

B3

Not used

B4

Not used

Size

Between 0 (zero) and 8 (eight)

 

This is a Block Tag with a variable size, depending on the value used in the B2 parameter.

Block Tags returned by the Configuration Parameters Tag

B2

Block Size

Parameters

0

2 (two)

Clock calibration constant, nominal temperature

1

2 (two)

Energy quantity, starting current

2

7 (seven)

Temperature calibration constant, voltage, and current calibration constants (six values)

3

3 (three)

Phase shift calibration constant (three values)

4

3 (three)

Active energy offset (three values)

5

3 (three)

Reactive energy offset (three values)

6

3 (three)

Hilbert transformation coefficients (three values)

7

3 (three)

Meter constant (imp/kWh), pulse duration, minimum pause duration

8

3 (three)

Telemeter output constant, pulse duration, minimum pause duration

9

0 (zero)

Manufacturer

10

0 (zero)

Model

11

0 (zero)

Firmware version

12

0 (zero)

Factory number

13

0 (zero)

User

14

0 (zero)

Location

15

2 (two)

Configuration bits

16

4 (four)

Numerator of current transformation coefficient, numerator of voltage transformation coefficient, denominator of current transformation coefficient, denominator of voltage transformation coefficient

17

8 (eight)

Nominal voltage, nominal current, nominal frequency, maximum current, maximum voltage, minimum frequency, maximum frequency

18

8 (eight)

Beginning of daylight savings (hour, day, and month), daylight savings deviation in hours, end of daylight savings (hour, day, and month), deviation for GMT (Greenwich Mean Time) format

19

2 (two)

Cyclic display duration in seconds, static display duration in seconds

20

3 (three)

Integration period, amount of periods averaged, billing day

21

4 (four)

Number of maximum demand (four most significant bits) and energy (four least significant bits), emergency tariff for maximum demand (four most significant bits), and energy (four least significant bits)

22

0 (zero)

Period in seconds for programmable channels

23

0 (zero)

Starting day of power quality monitoring

27

2 (two)

Function of telemeter outputs

28

2 (two)

Minimum temperature, maximum temperature

29

0 (zero)

Activation date of passive seasons

30

0 (zero)

Factory configuration

31

0 (zero)

Date and time of last clock change

32

4 (four)

Configuration of relay one

33

4 (four)

Configuration of relay two